EPJ Web of Conferences (Jan 2021)

USING PROMPT NEUTRON DECAY CONSTANT MEASUREMENTS TO OBTAIN ADDITIONAL KINETICS INFORMATION

  • McKenzie George,
  • Grove Travis,
  • Hutchinson Jesson

DOI
https://doi.org/10.1051/epjconf/202124709024
Journal volume & issue
Vol. 247
p. 09024

Abstract

Read online

Prompt neutron decay constant measurements are typically used to infer the prompt neutron lifetime in a chain-reacting system, but these measurements include much more information about the kinetics of the system. This work focuses specifically on the Rossi-α method of measuring the prompt neutron decay constant. The Rossi-α system of equations consists of five unknown parameters. With five unknowns and three equations, the system of equations solved by the Rossi-α measurement is under-determined. It has been postulated that a well posed problem can be formulated using independent measurement configurations on a single system. The external source strength, the effective delayed neutron fractions, and Diven’s parameter do not typically change for different configurations of a single experiment. If good detector geometry is chosen, the detector efficiency does not change for multiple measurements of a single experiment using Rossi-α measurements. By making these assumptions, there are only two unique variables. This knowledge can be used to solve for most of the unique parameters using two independent, unique Rossi-α measurements.