NeuroImage (Jun 2023)

MP-PCA denoising of fMRI time-series data can lead to artificial activation “spreading”

  • Francisca F. Fernandes,
  • Jonas L. Olesen,
  • Sune N. Jespersen,
  • Noam Shemesh

Journal volume & issue
Vol. 273
p. 120118

Abstract

Read online

MP-PCA denoising has become the method of choice for denoising MRI data since it provides an objective threshold to separate the signal components from unwanted thermal noise components. In rodents, thermal noise in the coils is an important source of noise that can reduce the accuracy of activation mapping in fMRI. Further confounding this problem, vendor data often contains zero-filling and other post-processing steps that may violate MP-PCA assumptions. Here, we develop an approach to denoise vendor data and assess activation “spreading” caused by MP-PCA denoising in rodent task-based fMRI data. Data was obtained from N = 3 mice using conventional multislice and ultrafast fMRI acquisitions (1 s and 50 ms temporal resolution, respectively), using a visual stimulation paradigm. MP-PCA denoising produced SNR gains of 64% and 39%, and Fourier Spectral Amplitude (FSA) increases in BOLD maps of 9% and 7% for multislice and ultrafast data, respectively, when using a small [2 2] denoising window. Larger windows provided higher SNR and FSA gains with increased spatial extent of activation that may or may not represent real activation. Simulations showed that MP-PCA denoising can incur activation “spreading” with increased false positive rate and smoother functional maps due to local “bleeding” of principal components, and that the optimal denoising window for improved specificity of functional mapping, based on Dice score calculations, depends on the data's tSNR and functional CNR. This “spreading” effect applies also to another recently proposed low-rank denoising method (NORDIC), although to a lesser degree. Our results bode well for enhancing spatial and/or temporal resolution in future fMRI work, while taking into account the sensitivity/specificity trade-offs of low-rank denoising methods.

Keywords