Arquivos Brasileiros de Cardiologia (Dec 2011)
Associação de níveis plasmáticos de PAI-1 e polimorfismo 4G/5G em pacientes com doença arterial coronariana PAI-1 4G/5G polymorphism and plasma levels association in patients with coronary artery disease
Abstract
FUNDAMENTO: O polimorfismo 4G/5G do inibidor ativador do plasminogênio tipo 1 (PAI-1) pode influenciar a expressão do PAI-1. Níveis plasmáticos elevados de PAI-1 estão associados com Doença Arterial Coronariana (DAC). OBJETIVO: O presente estudo investigou a influência do polimorfismo 4G/5G do PAI-1 nos níveis plasmáticos de PAI-1 e sua associação com DAC avaliada por angiografia coronária. MÉTODOS: Foi avaliada amostra de sangue de 35 indivíduos com artérias coronárias angiograficamente normais, 31 indivíduos apresentando ateromatose leve/moderada, 57 indivíduos apresentando ateromatose grave e 38 indivíduos saudáveis (controles). Em pacientes e controles, o polimorfismo 4G/5G do PAI-1 foi determinado por amplificação da proteína-C reativa utilizando primers específicos de alelo. Os níveis plasmáticos de PAI-1 foram quantificados pelo ensaio ELISA (American Diagnostica). RESULTADOS: Não houve diferença entre os grupos quanto a sexo, idade e índice de massa corporal. Níveis plasmáticos de PAI-1 e frequência do genótipo 4G/4G mostravam-se significativamente maiores no grupo com ateromatose grave em comparação com os outros grupos (p 70% (p BACKGROUND: Type-1 plasminogen activator inhibitor (PAI-1) 4G/5G polymorphism may influence the PAI-1 expression. High plasma levels of PAI-1 are associated with coronary artery disease (CAD). OBJECTIVE: This study investigated the influence of PAI-1 4G/5G polymorphism on plasma PAI-1 levels and its association with CAD assessed by coronary angiography. METHODS: Blood sample of 35 individuals with angiographycally normal coronary arteries, 31 individuals presenting mild/moderate atheromatosis, 57 individuals presenting severe atheromatosis and 38 healthy individuals (controls) were evaluated. In patients and controls, the PAI-1 4G/5G polymorphism was determined by PCR amplification using allele-specific primers. Plasma PAI-1 levels were quantified by ELISA assay (American Diagnostica). RESULTS: No difference was found between groups regarding age, gender and body mass index. Plasma PAI-1 levels and 4G/4G genotype frequency were significantly higher in the severe atheromatosis group compared to the other groups (p 70% (p<0.001). CONCLUSION: The most important finding of this study was the association between 4G/4G genotype, high plasma PAI-1 levels and coronary stenosis higher than 70% in Brazilian individuals. Whether high plasma PAI-1 levels are a decisive factor for atherosclerosis worsening or it is a consequence remains to be established.