Sensors (Aug 2024)

Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength

  • Samuel W. Oxford,
  • Neil D. Clarke,
  • Jason Tallis

DOI
https://doi.org/10.3390/s24155015
Journal volume & issue
Vol. 24, no. 15
p. 5015

Abstract

Read online

The reliability of the fixed-frame dynamometer for measuring isometric neck strength is established, but with limited field-based applications. This study aimed to establish the inter- and intra-session reliability of the peak force for neck flexors, extensors, and side flexors using the VALD ForceFrame and DynaMo and the force–time characteristics in the quadruped position (ForceFrame). Twenty-seven recreationally active males performed three repetitions of isometric neck flexion, extension, and side flexion over two sessions in random order using the VALD ForceFrame and DynaMo. Both devices demonstrated acceptable reliability, with the Forceframe ICC > 0.8 and CV% 0.76 and CV% 0.76) and left-side (ICC > 0.79) flexion and flexion (ICC > 0.75) across 50, 100, 150, and 200 ms. Statistical parametric mapping indicated no differences in ForceFrame-generated isometric force–time curves between sessions, though the CV was highest in the force development phase. The findings suggest that both tools can reliably assess neck strength, supporting their use in sports and clinical settings. However, assessment methods are not interchangeable, emphasising the need for standardised neck strength assessment approaches.