Brazilian Journal of Cardiovascular Surgery (Dec 2012)
Anastomose cavo-pulmonar associada ao suporte circulatório esquerdo comparada à assistência biventricular na falência cardíaca aguda Cavo-pulmonary anastomosis associated with left ventricular in comparison with biventricular circulatory support in acute heart failure
Abstract
OBJETIVO: Este estudo avaliou o desempenho hemodinâmico e as alterações miocárdicas decorrentes do emprego de dispositivos de assistência ventricular esquerda (DAVE), associado ou não à descompressão do ventrículo direito por meio de derivação cavo-pulmonar, sendo esses achados comparados ao emprego de assistência circulatória biventricular. MÉTODOS: Vinte e um suínos foram submetidos à indução de insuficiência cardíaca através de fibrilação ventricular, sendo a atividade circulatória mantida por DAVE durante 180 minutos. No grupo controle, foi apenas implantado o DAVE. No grupo derivação, além do DAVE foi realizada cirurgia de derivação cavo-pulmonar. No grupo biventricular, foi instituída assistência biventricular. Foram monitoradas as pressões intracavitárias por 3 horas de assistência e amostras do endocárdio dos dois ventrículos foram coletadas e analisadas à microscopia óptica e eletrônica. RESULTADOS: O lactato sérico foi significativamente menor no grupo biventricular (P=0,014). A diferença observada entre o fluxo do DAVE nos grupos derivação e controle (+55±14 ml/kg/min, P=0,072) não foi significativa, enquanto que o fluxo no grupo biventricular foi significativamente maior (+93±17 ml/kg/min, P=0,012) e se manteve estável durante o experimento. A pressão arterial média (PAM) se manteve constante apenas no grupo biventricular (POBJECTIVE: Right ventricular (RV) failure during left ventricular assist device (LVAD) support can result in severe hemodynamic compromise with high mortality. This study investigated the acute effects of cavo-pulmonary anastomosis on LVAD performance and RV myocardial compromise in comparison with biventricular circulatory support, in a model of biventricular failure. METHODS: LVAD support was performed by centrifugal pump in 21 pigs with severe biventricular failure obtained by FV induction. Animals were randomized to be submitted to cavo-pulmonary anastomosis, to biventricular circulatory support or to control group. They were maintained under circulatory support and hemodynamic monitoring for 3h. Venous lactate and cytokines serum levels were also obtained. Endocardium samples were analyzed by electronic microscopy. RESULTS: FV maintenance was responsible for acute LVAD impairment after 180 min in the control group. cavo-pulmonary anastomosis resulted in non-significant improvement of LVAD pump flow in relation to control group (+55±14 ml/kg/min, P=0.072), while animals under biventricular support maintained higher LVAD flow (+93±17 ml/kg/min, P=0.012). Mean arterial pressure remained constant only in biventricular group (P<0.001), which also presented decrease of right atrial and ventricular pressures. Similar increases in lactate and cytokines levels were observed in the three groups. Ultra-structural analysis documented low levels of myocardial swelling in the biventricular group (P=0.017). CONCLUSION: The concomitant use of cavo-pulmonary anastomosis during LVAD support in a pig model of severe biventricular failure resulted in non-significant improvement of hemodynamic performance and it did not effectively replace the use of biventricular support.