Tomography (Dec 2022)

Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study

  • Takeshi Oki,
  • Alan Kawarai Lefor,
  • Kentaro Nakamura,
  • Takahiro Higashi,
  • Isao Oki

DOI
https://doi.org/10.3390/tomography9010002
Journal volume & issue
Vol. 9, no. 1
pp. 12 – 24

Abstract

Read online

Background and Objectives: Percutaneous pedicle screw (PPS) placement is a minimally invasive spinal procedure that has been rapidly adopted over the last decade. However, PPS placement has elicited fear of increased radiation exposure from some surgeons, medical staff, and patients. This is because PPS placement is performed using a K-wire, and the operator must perform K-wire insertion into the pedicle under fluoroscopy. In order to prevent erroneous insertion, there are many occasions when direct insertion is required during radiation exposure, and the amount of radiation exposure to hands and fingers in particular increases. Although these problems are being addressed by navigation systems, these systems are still expensive and not widely available. Attempts have been made to address this situation using instrumentation commonly used in spinal surgery. First, it was considered to visualize anatomical bone markers using a tubular retractor and a microscope. In addition, the use of a self-drilling pin was adopted to locate the pedicle in a narrower field of view. Based on these considerations, a minimally invasive and highly accurate pedicle screw placement technique was developed while avoiding direct radiation exposure. This study evaluated radiation exposure and accuracy of pedicle screw placement using this new procedure in one-level, minimally invasive, transforaminal lumbar interbody fusion (MIS-TLIF). Materials and Methods: Data were collected retrospectively to review pedicle screw placement in single-level MIS TLIFs using a tubular retractor under a microscope. The total fluoroscopy time, radiation dose, and screw placement accuracy were reviewed. Extension of operating time was also evaluated. Results: Twenty-four patients underwent single-level MIS TLIFs, with placement of 96 pedicle screws. There were 15 females and 9 males, with an average age of 64.8 years and a mean body mass index of 25.5 kg/m2. The mean operating time was 201.8 min. The mean fluoroscopic time was 26.8 s. The mean radiation dose of the area dose product was 0.0706 mGy∗m2. The mean radiation dose of air kerma was 6.0 mGy. The mean radiation dose of the entrance skin dose was 11.31 mGy. Postoperative computed tomography scans demonstrated 93 pedicle screws confined to the pedicle (97%) and three pedicle screw breaches (3.2%; two lateral, one medial). A patient with screw deviation of the medial pedicle wall developed right-foot numbness necessitating reoperation. There were no complications after reoperation. The average added time with this combined procedure was 39 min (range 16–69 min) per patient. Conclusions: This novel pedicle screw insertion technique compares favorably with other reports in terms of radiation exposure reduction and accuracy and is also useful from the viewpoint of avoiding direct radiation exposure to hands and fingers. It is economical because it uses existing spinal surgical instrumentation.

Keywords