Restorative Dentistry & Endodontics (May 2011)

Evaluation of polymerization shrinkage stress in silorane-based composites

  • Seung-Ji Ryu,,
  • Ji-Hoon Cheon,
  • Jeong-Bum Min

DOI
https://doi.org/10.5395/JKACD.2011.36.3.188
Journal volume & issue
Vol. 36, no. 3
pp. 188 – 195

Abstract

Read online

Objectives The purpose of this study was to evaluate the polymerization shrinkage stress among conventional methacrylate-based composite resins and a silorane-based composite resin. Materials and Methods The strain gauge method was used for the determination of polymerization shrinkage strain. Specimens were divided by 3 groups according to various composite materials. Filtek Z-250 (3M ESPE) and Filtek P-60 (3M ESPE) were used as a conventional methacrylate-based composites and Filtek P-90 (3M ESPE) was used as a silorane-based composites. Measurements were recorded at each 1 second for the total of 800 seconds including the periods of light application. The results of polymerization shrinkage stress were statistically analyzed using One way ANOVA and Tukey test (p = 0.05). Results The polymerization shrinkage stress of a silorane-based composite resin was lower than those of conventional methacrylate-based composite resins (p 0.05). Conclusions Within the limitation of this study, silorane-based composites showed lower polymerization shrinkage stress than methacrylate-based composites. We need to investigate more into polymerization shrinkage stress with regard to elastic modulus of silorane-based composites for the precise result.