Applied Sciences (Mar 2020)

Monitoring of Grouting Compactness in Tendon Duct Using Multi-Sensing Electro-Mechanical Impedance Method

  • Bin Guo,
  • Dongdong Chen,
  • Linsheng Huo,
  • Gangbing Song

DOI
https://doi.org/10.3390/app10062018
Journal volume & issue
Vol. 10, no. 6
p. 2018

Abstract

Read online

The structural integrity of post-tensioning prestressed concrete structures with tendon ducts highly depends on the grouting quality in construction. This paper proposes a real-time approach to monitoring the grouting compactness in tendon ducts using the multi-sensing electro-mechanical impedance (EMI) method. When Lead Zirconate Titanate (PZT) transducers with different pre-selected dimensions are serially connected and mounted on a structure at distributed locations, each PZT provides unique resonance frequency coupled with the local structural physical property. Therefore, the impedance with multiple peaks of the serially connected multiple PZTs can be captured during a single measurement, which significantly simplifies the measurement procedure and reduces the data processing time. In addition, the wiring for the PZT sensors is also simplified. In this research, the feasibility of the proposed method was experimentally and numerically investigated to monitor the grouting compactness in a tendon duct specimen. The 3-dB mean absolute percentage deviation (MAPD) was applied to quantify the variations of the impedance signatures measured from five different grouting levels. Both experimental and numerical results verify the feasibility of using the proposed method for monitoring the grouting compactness in tendon ducts.

Keywords