Viruses (Jun 2024)

Adapting Real-Time Lung Function Measurements for SARS-CoV-2 Infection Studies in Syrian Hamsters

  • Rineke de Jong,
  • Wout Nuiten,
  • Albertjan ter Heide,
  • Wilfred Hamstra,
  • Sandra Vreman,
  • Nadia Oreshkova,
  • Katrin E. Wiese,
  • Nora M. Gerhards

DOI
https://doi.org/10.3390/v16071022
Journal volume & issue
Vol. 16, no. 7
p. 1022

Abstract

Read online

Pulmonary function examinations are critical to assess respiratory disease severity in patients. In preclinical rodent models of viral respiratory infections, however, disease is frequently evaluated based on virological, pathological and/or surrogate clinical parameters, which are not directly associated with lung function. To bridge the gap between preclinical and clinical readouts, we aimed to apply unrestrained whole-body plethysmography (WBP) measurements in a SARS-CoV-2 Syrian hamster challenge model. While WBP measurements are frequently used for preclinical research in mice and rats, results from studies in hamsters are still limited. During unrestrained WBP measurements, we obtained highly variable breathing frequency values outside of the normal physiological range for hamsters. Importantly, we observed that animal movements were recorded as breaths during WBP measurements. By limiting animal movement through either mechanical or chemical restraint, we improved the reliability of the lung function readout and obtained breathing frequencies that correlated with clinical signs when comparing two different variants of SARS-CoV-2 post-inoculation. Simultaneously, however, new sources of experimental variation were introduced by the method of restraint, which demands further optimalization of WBP measurements in Syrian hamsters. We concluded that WBP measurements are a valuable refinement either in combination with video recordings or if average values of measurements lasting several hours are analyzed.

Keywords