Physical Review Special Topics. Accelerators and Beams (Apr 2015)

Measurements of copper and cesium telluride cathodes in a radio-frequency photoinjector

  • Eduard Prat,
  • Simona Bettoni,
  • Hans-Heinrich Braun,
  • Romain Ganter,
  • Thomas Schietinger

DOI
https://doi.org/10.1103/PhysRevSTAB.18.043401
Journal volume & issue
Vol. 18, no. 4
p. 043401

Abstract

Read online Read online

Radio-frequency (rf) photoinjectors are commonly used to generate intense bright electron beams for a wide range of applications, most notably as drivers for X-ray Free-Electron Lasers. The photocathode, mounted inside an rf gun and illuminated by a suitable laser, thereby plays a crucial role as the source of the electrons. The intrinsic emittance and the quantum efficiency of the electron source are determined by the properties of the photocathode’s surface material. We present measurements of the intrinsic emittance and the quantum efficiency performed with copper and cesium telluride cathodes in the same rf photoinjector, thus comparing, for the first time, the performance of metal and semiconductor cathodes under the same conditions. Our results are consistent with theoretical expectations and show that the difference in intrinsic emittance for the two types of material is not significant in view of accelerator applications. We conclude that cesium telluride photocathodes provide a much higher quantum efficiency at essentially negligible degradation in beam emittance.