International Journal of Ophthalmology (Mar 2016)

A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery

  • Yi-Bo Yu,
  • Ya-Nan Zhu,
  • Wei Wang,
  • Yi-Dong Zhang,
  • Yin-Hui Yu,
  • Ke Yao

DOI
https://doi.org/10.18240/ijo.2016.03.13
Journal volume & issue
Vol. 9, no. 3
pp. 399 – 405

Abstract

Read online

AIM: To evaluate the clinical and optical outcomes after clear corneal incision cataract surgery (CICS) with three different incision sizes (1.8, 2.0 and 3.0 mm). METHODS: Eyes of 150 patients with age-related cataract scheduled for coaxial cataract surgery were randomized to three groups: 1.8, 2.0, or 3.0 mm CICS. Intraoperative data and postoperative outcomes including surgically induced astigmatism (SIA), the corneal incision thickness, wavefront aberrations and modulation transfer function (MTF) of cornea were obtained. RESULTS: There were no significant differences among the three groups in demographic characteristics and intraoperative outcome. The 1.8 and 2.0 mm microincisions showed more satisfactory clinical outcomes than the 3.0 mm incision. The 1.8 mm incision showed significantly less SIA than the 2.0 mm incision until postoperative 1mo (P0.05). CONCLUSION: Converting from 3.0 mm CICS to 1.8 or 2.0 mm CICS result in better clinical and optical outcomes. However, when incision is 1.8 mm, the benefits from further reduction in size compared with 2.0 mm are limited. The necessity to reduce the incision size is to be deliberated.