Water (May 2018)

The Testing of Standard and Recyclable Filter Media to Eliminate Hydrogen Sulphide from Sewerage Systems

  • Petr Hluštík,
  • Jiří Novotný

DOI
https://doi.org/10.3390/w10060689
Journal volume & issue
Vol. 10, no. 6
p. 689

Abstract

Read online

This article focuses on the subject of odours forming in sewage transfer chambers with displacement inlets, as well as the odours in their vicinity. It further covers the locations of odour formation, factors influencing the formation of hydrogen sulphide in wastewater, methods of removing hydrogen sulphide from wastewater, and laboratory testing of filtration media efficacy at various concentration levels of H2S. The laboratory testing of filtration media efficacy is performed for products normally used by sewerage system operators guaranteeing the elimination of hydrogen sulphide (activated carbon, natural minerals and gels), recyclable materials (paper) and secondary raw materials in the field of waste management (biochar—the final product of microwave pyrolysis). Odour generated by sewerage systems is a secondary issue faced by all sewerage system operators, who sustain considerable expense in corrective measures to address this problem. The most economical and widespread measure used by those operators is hydrogen sulphide removal by filtration (filtration materials). Filtration media are installed in special cartridges under sewage covers in locations where the irritating odour is formed. These filtration cartridges, designed solely to eliminate odour from the surroundings, show various degrees of efficacy in removing H2S.

Keywords