PLoS ONE (Jan 2018)

Pulmonary vein volume predicts the outcome of radiofrequency catheter ablation of paroxysmal atrial fibrillation.

  • Keiko Shimamoto,
  • Fumiharu Miura,
  • Yuji Shimatani,
  • Kenji Nishioka,
  • Ichiro Inoue

DOI
https://doi.org/10.1371/journal.pone.0201199
Journal volume & issue
Vol. 13, no. 7
p. e0201199

Abstract

Read online

PURPOSE:Catheter ablation of atrial fibrillation (AF) is an effective therapy for selected groups of patients. We evaluated whether quantification of left atrium (LA) or pulmonary vein (PV) by using multi-detector computed tomography (MDCT) may predict the success rate of PV isolation procedure. METHODS:We included 118 patients younger than 65 years with symptomatic AF (73 paroxysmal, PAF; 45 non-paroxysmal, non-PAF). All patients underwent 256-slice MDCT prior to circumferential PV isolation to evaluate anatomy, volume and dimensions of LA and PV. RESULTS:After a mean follow-up of 14 months, complete success was achieved in 50 patients (68.5%) of PAF and in 26 patients (57.8%) of non-PAF. In the PAF group, total PV volume was found to be an independent predictor of AF recurrence, whereas LA volume was not. Logistic regression analysis showed that the probability of AF recurrence was higher in patients with total PV volume greater than 12.0 cm3/BSA (m2) (AUC 0.682, 95%CI 0.541-0.822). In the non-PAF group, no independent risk factor of LA or PV size was observed for the postoperative recurrence. CONCLUSIONS:The PV volume quantification may predict the success of AF ablation in PAF patients.