Cardiology and Therapy (Mar 2023)

Impact of Intraprocedural Pressure Changes on Hemodynamic Outcome During Self-Expanding TAVR

  • Jouni Pykäri,
  • Tuija Vasankari,
  • Antti Ylitalo,
  • Pekka Porela,
  • Tuomas Paana,
  • Markus Malmberg,
  • Sanna Laurila,
  • Juho Koskinen,
  • Tero Koivisto,
  • Mikko Savontaus

DOI
https://doi.org/10.1007/s40119-023-00307-8
Journal volume & issue
Vol. 12, no. 2
pp. 361 – 369

Abstract

Read online

Abstract Introduction During the transcatheter aortic valve replacement (TAVR) procedure, hemodynamic measurements can be used to evaluate transcatheter heart valve (THV) performance. We hypothesized that the occurrence of a significant decrease in invasive aortic pressure immediately after annular contact by a self-expanding THV indicates effective annular sealing. This phenomenon could thus be used as a marker for the occurrence of paravalvular leak (PVL). Methods Thirty-eight patients undergoing TAVR procedure with a self-expandable Evolut R or Evolut Pro (Medtronic) valve prosthesis were included in the study. Drop in aortic pressure during valve expansion was defined as a decrease in systolic pressure of 30 mmHg immediately after annular contact. The primary endpoint was the occurrence of more than mild PVL immediately after valve implantation. Results A pressure drop was seen in 60.5% (23/38) of patients. More than mild PVL requiring balloon post-dilatation (BPD) was significantly more frequent in patients who did not have a systolic pressure decrease > 30 mmHg during valve implantation (46.7% [7/15] vs. 13.0% [3/23], respectively; p = 0.03). Patients without a systolic pressure decrease > 30 mmHg also had a lower mean cover index on computed tomography analysis (16.2% vs. 13.3%; p = 0.016). The 30-day outcomes were similar between the two groups, and echocardiography at 30 days demonstrated more than none/trace PVL in 21.1% (8/38) of patients, with no difference between the two groups. Conclusion A decrease in aortic pressure after annular contact is associated with an increased probability of good hemodynamic outcome after self-expanding TAVR implantation. In addition to other methods, this parameter could be used as an additional marker for optimal valve positioning and hemodynamic outcome during the implantation procedure.

Keywords