IET Power Electronics (May 2024)

Fault‐tolerant control of current residual vector three‐phase four‐switch motor drive system based on MLD model

  • Dezhi Chen,
  • Wenbo Zhao,
  • Yun Sun,
  • Wenliang Zhao,
  • Zhixiang Zhang,
  • Ziyuan Xin

DOI
https://doi.org/10.1049/pel2.12688
Journal volume & issue
Vol. 17, no. 6
pp. 731 – 751

Abstract

Read online

Abstract Aiming at the problem of single‐phase switch tube open circuit fault in inverters, a current residual vector three‐phase four‐switch fault‐tolerant control strategy based on the mixed logic dynamic (MLD) model of permanent magnet synchronous motor (PMSM) drive system is proposed. Firstly, the MLD and three‐phase four‐switch mathematical models of the motor drive system are established and a calculation method of DC bus capacitance is proposed. Secondly, to improve the dynamic performance of the motor, an improved vector control based on the MLD model is proposed. Finally, by setting the threshold and dividing the area of the current residual vector, the accuracy of inverter fault diagnosis is improved, and the fast and smooth switching of the drive system after the fault is realized. Simulation and experimental results show that this strategy can effectively reduce the influence of calculation error and system noise, and has strong robustness for the change of motor speed and load.

Keywords