Mathematics (Oct 2021)

Comparative Study of Energy Consumption and CO<sub>2</sub> Emissions of Variable-Speed Electric Drives with Induction and Synchronous Reluctance Motors in Pump Units

  • Victor Goman,
  • Vladimir Prakht,
  • Vadim Kazakbaev,
  • Vladimir Dmitrievskii

DOI
https://doi.org/10.3390/math9212679
Journal volume & issue
Vol. 9, no. 21
p. 2679

Abstract

Read online

This study carried out a comparative analysis of indicators of electricity consumption and CO2 emissions for four-pole induction motors (IMs) of efficiency classes IE3 and IE4 with a rated power of 2.2–200 kW in a variable speed pump unit. In addition, innovative IE4 converter-fed synchronous reluctance motors (SynRMs) were evaluated. The comparison was derived from the manufacturer’s specifications for the power drive systems (PDSs) at various rotational speeds and loads. The results showed that the emission indicators for IE3 class motors were significantly worse compared with IE4 class motors for low power ratings, which make up the vast majority of electric motors in service. This justifies expanding the mandatory power range for IE4 motors to at least 7.5–200 kW or even 0.75–200 kW, as it will dramatically contribute to the achievement of the new ambitious goals for reducing greenhouse gas emissions. In addition, the operational advantages of IE4 SynRMs over IE4 IMs were demonstrated, such as their simpler design and manufacturing technology at a price comparable to that of IE3 IMs.

Keywords