Point-of-care haemoglobin accuracy and transfusion outcomes in non-cardiac surgery at a Canadian tertiary academic hospital: protocol for the PREMISE observational study

  • Dean A Fergusson,
  • Ranjeeta Mallick,
  • Tim Ramsay,
  • Daniel I McIsaac,
  • Alan Tinmouth,
  • Guillaume Martel,
  • Justin Presseau,
  • François Martin Carrier,
  • Karine Brousseau,
  • Leah Monette,
  • Aklile Workneh,
  • Julie Shaw,
  • Christopher Wherrett

DOI
https://doi.org/10.1136/bmjopen-2023-075070
Journal volume & issue
Vol. 13, no. 12

Abstract

Read online

Introduction Transfusions in surgery can be life-saving interventions, but inappropriate transfusions may lack clinical benefit and cause harm. Transfusion decision-making in surgery is complex and frequently informed by haemoglobin (Hgb) measurement in the operating room. Point-of-care testing for haemoglobin (POCT-Hgb) is increasingly relied on given its simplicity and rapid provision of results. POCT-Hgb devices lack adequate validation in the operative setting, particularly for Hgb values within the transfusion zone (60–100 g/L). This study aims to examine the accuracy of intraoperative POCT-Hgb instruments in non-cardiac surgery, and the association between POCT-Hgb measurements and transfusion decision-making.Methods and analysis PREMISE is an observational prospective method comparison study. Enrolment will occur when adult patients undergoing major non-cardiac surgery require POCT-Hgb, as determined by the treating team. Three concurrent POCT-Hgb results, considered as index tests, will be compared with a laboratory analysis of Hgb (lab-Hgb), considered the gold standard. Participants may have multiple POCT-Hgb measurements during surgery. The primary outcome is the difference in individual Hgb measurements between POCT-Hgb and lab-Hgb, primarily among measurements that are within the transfusion zone. Secondary outcomes include POCT-Hgb accuracy within the entire cohort, postoperative morbidity, mortality and transfusion rates. The sample size is 1750 POCT-Hgb measurements to obtain a minimum of 652 Hgb measurements <100 g/L, based on an estimated incidence of 38%. The sample size was calculated to fit a logistic regression model to predict instances when POCT-Hgb are inaccurate, using 4 g/L as an acceptable margin of error.Ethics and dissemination Institutional ethics approval has been obtained by the Ottawa Health Science Network—Research Ethics Board prior to initiating the study. Findings from this study will be published in peer-reviewed journals and presented at relevant scientific conferences. Social media will be leveraged to further disseminate the study results and engage with clinicians.