Semina: Ciências Exatas e Tecnológicas (May 2015)

Carbon nanotubes paste sensor modified with bismuth film for determination of metallic ions in ethanol fuel

  • Felipe Augusto Gorla,
  • Fernanda Midori de Oliveira,
  • Eduardo H. Duarte,
  • Ana E. P. de Mattos,
  • Elisângela Tavares da Silva,
  • Olívio F. Galão,
  • Dionísio Borsato,
  • Mariana G. Segatelli,
  • Cesar Ricardo Teixeira Tarley

DOI
https://doi.org/10.5433/1679-0375.2015v36n1p41
Journal volume & issue
Vol. 36, no. 1
pp. 41 – 50

Abstract

Read online

In the present study an anodic stripping voltammetric method using a bismuth film modified carbon nanotubes paste electrode for simultaneous determination of metals Zn2+, Cd2+and Pb2+in ethanol fuel is described. The metallic ions were preconcentrated on the bismuth film in the time and deposition potential of 500 s and -1.2 V and the stripping step was carried out by square wave voltammetry (frequency of 15 Hz, pulse amplitude of 25 mV and potential step of 5 mV). Acetate buffer at 0.1 mol L-1concentration and pH 4.5 was used as support electrolyte. The method showed linearity including the analytical blank up to 48.39 ?g L-1 for the metals and the obtained limits of detection were 3.36, 0.32 and 0.47 ?g L-1for Zn2+, Cd2+and Pb2+, respectively. The proposed method was applied in ethanol fuel samples.

Keywords