Flexible Miniaturized Electrochemical Sensors Based on Multiwalled Carbon Nanotube-Chitosan Nanomaterial for Determination of Nitrite in Soil Solutions
Ana-Maria Gurban,
Lucian-Gabriel Zamfir,
Petru Epure,
Ioana-Raluca Șuică-Bunghez,
Raluca Mădălina Senin,
Maria-Luiza Jecu,
Maria Lorena Jinga,
Mihaela Doni
Affiliations
Ana-Maria Gurban
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Lucian-Gabriel Zamfir
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Petru Epure
EPI-SISTEM SRL, 17A Livezii, Săcele, 505600 Brașov, Romania
Ioana-Raluca Șuică-Bunghez
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Raluca Mădălina Senin
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Maria-Luiza Jecu
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Maria Lorena Jinga
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Mihaela Doni
National Research & Development Institute for Chemistry & Petrochemistry—ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania
Flexible screen-printed electrodes (SPE) were modified in a simple manner with different composite nanomaterials based on carbon allotropes, polymers, and metallic nanoparticles, for amperometric detection of nitrites in soil. Multiwalled carbon nanotubes (MWCNT), chitosan (CS), silver nanoparticles (AgNPs), 1,8-diaminonaphthalene (1,8-DAN), and a sol-gel (SG) matrix were used for modification of the carbon paste working electrodes. Sensitive and selective detection of nitrite was achieved by using a MWCNT-CS-modified sensor, in acetate buffer at pH 5, at an applied potential of 0.58 V vs. Ag/AgCl. The MWCNT-CS-based sensor displayed a specific sensitivity of 204.4 mA·M−1·cm−2, with a detection limit of 2.3 µM (S/N = 3) in a linear range up to 1.7 mM, showing good stability, reproducibility, and selectivity towards other interfering species. A miniaturized portable system using the developed flexible electrochemical MWCNT-CS-based sensors was dedicated for the detection of nitrite in different samples of soil solutions extracted by using suction lysimeters.