Metrological aspects of international intercomparison of passive radon detectors under field conditions in Marie Curie’s tunnel in Lurisia
Cardellini Francesco,
Chiaberto Enrico,
Garlati Luisella,
Giuffrida Daniele,
Leonardi Federica,
Magnoni Mauro,
Minchillo Gianfranco,
Prandstatter Anna,
Serena Elena,
Trevisi Rosabianca,
Tripodi Rosamaria,
Veschetti Miriam
Affiliations
Cardellini Francesco
ENEA-INMRI, Rome, Italy
Chiaberto Enrico
Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
Garlati Luisella
Politecnico di Milano, Milano, Italy
Giuffrida Daniele
Federal Authority for Nuclear Regulation (FANR), United Arab Emirates
Leonardi Federica
Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
Magnoni Mauro
Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
Minchillo Gianfranco
Joint Research Centre (JRC), Ispra, Italy
Prandstatter Anna
Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
Serena Elena
Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
Trevisi Rosabianca
Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
Tripodi Rosamaria
Agenzia Regionale per la Protezione Ambuentale (ARPA), Piemonte, Ivrea, Italy
Veschetti Miriam
Italian National Workers Compensation Authority (INAIL), Department of Medicine, Epidemiology, Occupational and Environmental Hygiene, Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) Italy, Tel.: + 39 06 94181 265
In 2014, an intercomparison exercise of passive radon detectors under field conditions in the Marie Curie’s tunnel belonging to the Lurisia spas complex (Lurisia, Piedmont, Italy) has been held. Radon activity concentration in the tunnel was measured with six radon active monitors, previously calibrated at ENEA-INMRI facilities. In the present paper, a synthesis of the metrological aspects of the intercomparison is given. Indeed particular attention was paid to metrological characterization of radon monitors and their response upon ambient conditions. Correction factors have been defined to be applied when measurements are performed in severe environmental conditions. In particular, it has been found that monitors are particularly sensitive to the effect of air density: the AlphaGUARD (AG-SAPHYMO, GmbH) efficiency decreases with the air density, while for the MR1 PLUS (Tesys, Italy), the opposite applies. When the reference monitors were placed into the Marie Curie’s tunnel, to the recorded average radon concentrations correction factors were applied. After the correction the difference between data coming from AG and MR1 PLUS is within the 1.7%.