Journal of Cardiothoracic Surgery (Oct 2022)

Expanding perigraft seroma after ascending aorta replacement

  • Shinji Kanemitsu,
  • Shunsuke Sakamoto,
  • Satoshi Teranishi,
  • Toru Mizumoto

DOI
https://doi.org/10.1186/s13019-022-02018-y
Journal volume & issue
Vol. 17, no. 1
pp. 1 – 4

Abstract

Read online

Abstract Background Perigraft seroma is a persistent and sterile fluid confined within a fibrous pseudomembrane surrounding a graft that develops after graft replacement. Development of perigraft seroma is an uncommon complication that occurs after the surgical repair of the thoracic aorta using woven polyester grafts. mechanism underlying perigraft seroma formation remains unclear. Case presentation Herein, we describe the case of 77-year-old man who underwent repeat sternotomy for the treatment of large perigraft seroma 1 year after ascending aorta replacement for acute type A dissection. After removing a cloudy yellow fluid, we covered the prosthetic graft with fibrin glue and wrapped it with a new graft. Bacterial culture and laboratory examination of the fluid confirmed the final diagnosis of perigraft seroma, and there was no evidence of recurrence. The area in which fluid accumulated around the graft shrunk 1 year after surgery. Conclusions The cause of a expanding perigraft after repair of the thoracic aorta remains unknown. Physicians should be aware that chronic expanding mediastinal seroma with Dacron grafts is one of the rare postoperative complications of thoracic aortic surgery. Applying fibrin glue to the graft surface might effectively prevent the recurrence of perigraft seroma.

Keywords