Metals (Jan 2022)

Performance of a Nozzle to Control Bath Level Oscillations and Turbulence of the Metal-Flux Interface in Slab Molds

  • María Guadalupe González-Solórzano,
  • Rodolfo Davila Morales,
  • Javier Guarneros,
  • Carlos Rodrigo Muñiz-Valdés,
  • Alfonso Nájera Bastida

DOI
https://doi.org/10.3390/met12010140
Journal volume & issue
Vol. 12, no. 1
p. 140

Abstract

Read online

The characterization of the turbulent flow of liquid steel in a slab mold using a commercial nozzle was carried out through physical experiments and mathematical models. Six ultrasonic sensors were located at each side of the nozzle to obtain real-time plotting of the bath levels during the experimental time. An ultrasonic transducer located in the mold, 20 mm below the meniscus, determines the velocities and the turbulent variables along with the distance from the narrow face to the position of the nozzle’s outer wall. These data, together with the mathematical simulations, demonstrated a high correlation of bath level oscillations and the time-dependent behavior of the discharging jets. The flow inside the mold shows low-frequency non-symmetric patterns without a severe turbulent in the meniscus. The source of this instability is the partial opening of the slide valve gate used to control the mass flow of liquid.

Keywords