E3S Web of Conferences (Jan 2020)
The correlation analysis of TOC, CODCr and fluorescence characteristics in MPR
Abstract
Water samples from different biochemical reaction time in one reactor period in Micro-Pressure Inner-Loop Bioreactor (MPR) were measured respectively with adopt Excitation-emission matrix (EEM) fluorescence spectroscopy, Total organic carbon (TOC) and chemical oxygen demand (CODCr),analyzed the correlation among the fluorescence integrates volume, TOC and CODCr.Results showed that with the increase of biochemical treatment time, sewage fluorescence integrates volume declined significantly, known fluorescence integrates volume, CODCr and TOC value better correlation, by fluorescence spectrometry analyzed fluorescence characteristics of sewage to determine the organic wastewater degradation effect, can be simpler and more rapid the judgment of the sewage treatment effect.