Journal of Veterinary Internal Medicine (May 2020)

Detection of congestive heart failure by Doppler echocardiography in cats with hypertrophic cardiomyopathy

  • Michelle N. Rohrbaugh,
  • Karsten E. Schober,
  • Jaylyn D. Rhinehart,
  • John D. Bonagura,
  • Amy Habing,
  • Vedat Yildiz

DOI
https://doi.org/10.1111/jvim.15777
Journal volume & issue
Vol. 34, no. 3
pp. 1091 – 1101

Abstract

Read online

Abstract Background Left‐sided congestive heart failure (CHF) is characterized by increased filling pressures and related Doppler echocardiographic (DE) filling patterns. Hypothesis Doppler echocardiographic variables of left ventricular filling derived from transmitral flow, pulmonary vein flow, and tissue Doppler can be used to detect CHF in cats with hypertrophic cardiomyopathy (HCM). Animals Forty‐seven client‐owned cats. Methods Prospective clinical cohort study. Cats underwent physical examination, thoracic radiography, analysis of N‐terminal pro‐brain natriuretic peptide (NT‐proBNP), and transthoracic echocardiography and were divided into 3 age‐matched groups: Group 1 (apparently healthy control), Group 2 (preclinical HCM), and Group 3 (HCM and CHF). Measured and calculated variables included respiratory rate, DE estimates, serum NT‐proBNP concentration, and radiographic CHF score. Groups were compared using ANOVA, and receiver operating characteristic (ROC) curve and multivariate analyses were used to identify diagnostic cutoffs for the detection of CHF. Results Fifteen cats were in Group 1, 17 in Group 2, and 15 in Group 3. The ROC analysis indicated that the ratio of peak velocity of early diastolic transmitral flow to peak velocity of late diastolic transmitral flow (area under the curve [AUC], 1.0; diagnostic cutoff, 1.77; P = .001), ratio of left atrial size to aortic annular dimension (AUC, 0.91; diagnostic cutoff, 1.96; P = .003), left atrial diameter (AUC, 0.89; cutoff, 18.5 mm; P = .004), diastolic functional class (AUC, 0.89; cutoff, class 2; P = .005), respiratory (AUC, 0.79; cutoff, 36 breaths per minute [brpm]; P = .02), and the ratio of the peak velocity of fused early and late transmitral flow velocities to the peak velocity of the fused early and late diastolic tissue Doppler waveforms (AUC, 0.74; cutoff, 15.1; P = .05) performed best for detecting CHF. Conclusions and Clinical Importance Various DE variables can be used to detect CHF in cats with HCM. Determination of the clinical benefit of such variables in initiating treatments and assessing treatment success needs further study.

Keywords