Brazilian Journal of Radiation Sciences (Oct 2022)

Passive Autocatalytic Recombiner Perfomance Assessment Using COCOSYS

  • hugo pontes,
  • gil teixeira,
  • julian shorto,
  • Alfredo abe,
  • Cláudia Giovedi

DOI
https://doi.org/10.15392/2319-0612.2022.1906
Journal volume & issue
Vol. 10, no. 3A

Abstract

Read online

The progression of a severe accident in nuclear reactors is composed by a diversity of phenomena that are Beyond Design Basis, such as Direct Containment Heating (DCH), Molten Corium Concrete Interaction (MCCI), hydrogen detonation, and others. Currently, there are several devices and systems that allow mitigating the progression of this events, avoiding the failure of the physical barriers between the nuclear power plant and the environmental. In this context, the present work aims to reproduce the HR-14 experiment carried out at the Thermal-hydraulic, Hydrogen, Aerosols and Iodine (THAI) test facility through the Passive Autocatalytic Recombiners (PAR) performance assessment with the COCOSYS code. The analysis of the convergence of the results was performed using the Fast Fourier Transform Based Method (FFTBM) and showed that the results had sufficient accuracy with the experimental data.

Keywords