Heliyon (Mar 2024)

Structural performance of detachable precast concrete column-column joint

  • H. Zhan,
  • M. Ye,
  • J. Jiang,
  • Y. Gao,
  • C.W. Zheng,
  • S.C. Duan

Journal volume & issue
Vol. 10, no. 5
p. e27308

Abstract

Read online

A novel type of detachable precast concrete column-column joint (DPC) is proposed in this study to solve the problems in current column-column dry connections including complex load path, uncertainty of structural stiffness of beam-column joints and inconvenience for disassembly. The dry connection technology is applied by composing of steel plate and concrete. Finite element models of DPC were created to study its structural performance including hysteresis curve, skeleton curve, ductility, and energy dissipation capacity. The benchmark models are firstly established and validated against the test data and after that a small-scale parametric study is prepared. The effect of axial pressure ratio and eccentricity distance size on the seismic performance of DPC was studied. Results indict that the optimal value of axial pressure ratio ranges from 0.5 to 0.7. With increase of the axial pressure ratio, the ductility coefficient shows a decreasing trend in general. The eccentricity has little effect on the energy dissipation capacity of the joint.

Keywords