Case Reports in Dentistry (Jan 2015)

A Rare Case of a Lost Suture Needle during Third Molar Surgery

  • Sertac Aktop,
  • Gokhan Gocmen,
  • M. Elif Özturk,
  • Onur Gonul,
  • Altan Varol

DOI
https://doi.org/10.1155/2015/372153
Journal volume & issue
Vol. 2015

Abstract

Read online

The authors report a case that is started with a simple upper third molar’s surgical extraction and a broken 3.0 suture needle tip incident occurred. Broken fragment’s localization has been detected with 3D cone beam computed tomography (CBCT). Needle tip has been reached with the help of CBCT vision. CBCT’s benefits have been discussed on these types of cases and further migration of the needle tip during surgical procedure is reported.