Journal of Medical Internet Research (Oct 2020)

Assessment of a Personal Interactive Carbon Monoxide Breath Sensor in People Who Smoke Cigarettes: Single-Arm Cohort Study

  • Marler, Jennifer D,
  • Fujii, Craig A,
  • Wong, Kristine S,
  • Galanko, Joseph A,
  • Balbierz, Daniel J,
  • Utley, David S

DOI
https://doi.org/10.2196/22811
Journal volume & issue
Vol. 22, no. 10
p. e22811

Abstract

Read online

BackgroundTobacco use is the leading cause of preventable morbidity and mortality. Existing evidence-based treatments are underutilized and have seen little recent innovation. The success of personal biofeedback interventions in other disease states portends a similar opportunity in smoking cessation. The Pivot Breath Sensor is a personal interactive FDA-cleared (over-the-counter) device that measures carbon monoxide (CO) in exhaled breath, enabling users to link their smoking behavior and CO values, and track their progress in reducing or quitting smoking. ObjectiveThe objective of this study is to assess the Pivot Breath Sensor in people who smoke cigarettes, evaluating changes in attitudes toward quitting smoking, changes in smoking behavior, and use experience. MethodsUS adults (18-80 years of age, ≥10 cigarettes per day [CPD]) were recruited online for this remote 12-week study. Participants completed a screening call, informed consent, and baseline questionnaire, and then were mailed their sensor. Participants were asked to submit 4 or more breath samples per day and complete questionnaires at 1-4, 8, and 12 weeks. Outcomes included attitudes toward quitting smoking (Stage of Change, success to quit, and perceived difficulty of quitting), smoking behavior (quit attempts, CPD reduction, and 7-, 30-day point prevalence abstinence [PPA]), and use experience (impact and learning). ResultsParticipants comprised 234 smokers, mean age 39.9 (SD 11.3) years, 52.6% (123/234) female, mean CPD 20.3 (SD 8.0). The 4- and 12-week questionnaires were completed by 92.3% (216/234) and 91.9% (215/234) of participants, respectively. Concerning attitude outcomes, at baseline, 15.4% (36/234) were seriously thinking of quitting in the next 30 days, increasing to 38.9% (84/216) at 4 weeks and 47.9% (103/215) at 12 weeks (both P196/214) indicated the sensor taught them about their CO levels and smoking behavior, and 73.1% (166/227) reported that seeing their CO values made them want to quit smoking. ConclusionsUse of the Pivot Breath Sensor resulted in a significant increase in motivation to quit, a reduction in CPD, and favorable quit attempt rates. These outcomes confer increased likelihood of quitting smoking. Accordingly, the results support a role for biofeedback via personal CO breath sampling in smoking cessation. Trial RegistrationClinicalTrials.gov NCT04133064; https://clinicaltrials.gov/ct2/show/NCT04133064