Sensors (Feb 2024)
Measurement of Soot Concentration in Burner Diffusion Flames through Emission Spectroscopy with Particle Swarm Optimization
Abstract
Measuring soot concentration in a burner flame is essential for an in-depth understanding of the formation mechanism and to abate its generation. This paper presents an improved emission spectroscopy (ES) method that uses an adaptive particle swarm optimization (APSO) algorithm for measuring the concentration of soot in methane burner flames. Experimental tests were conducted on a laboratory-scale facility under a methane flowrate ranging between 0.6 and 0.9 L/min. A comparison analysis of the soot concentration measured by the ES method, the improved emission spectroscopy (IES) method, and the thermocouple particle density (TPD) method (as a reference) was conducted. The ES method obtained a maximum absolute deviation of 0.84 ppm from the average soot concentration at the three measurement points compared to the TPD method, while that of the IES was only 0.09 ppm. The experimental results demonstrate that the proposed IES method can obtain a more accurate soot concentration of diffusion flames.