Frontiers in Cardiovascular Medicine (Jan 2023)

Ultra-high pressure balloon angioplasty for pulmonary artery stenosis in children with congenital heart defects: Short- to mid-term follow-up results from a retrospective cohort in a single tertiary center

  • Shuliang Xia,
  • Shuliang Xia,
  • Jianbin Li,
  • Jianbin Li,
  • Li Ma,
  • Li Ma,
  • Yanqin Cui,
  • Yanqin Cui,
  • Techang Liu,
  • Techang Liu,
  • Zhouping Wang,
  • Zhouping Wang,
  • Fengxiang Li,
  • Fengxiang Li,
  • Xumei Liu,
  • Xumei Liu,
  • Shan Li,
  • Shan Li,
  • Lu Sun,
  • Lu Sun,
  • Lin Hu,
  • Lin Hu,
  • Yubin Liu,
  • Xun Ma,
  • Xun Ma,
  • Xinxin Chen,
  • Xinxin Chen,
  • Xu Zhang,
  • Xu Zhang

DOI
https://doi.org/10.3389/fcvm.2022.1078172
Journal volume & issue
Vol. 9

Abstract

Read online

ObjectiveBalloon angioplasty (BA) has been the treatment of choice for pulmonary artery stenosis (PAS) in children. There remains, however, a significant proportion of resistant lesions. The ultra-high pressure (UHP) balloons might be effective in a subset of these lesions. In this study, we analyzed the safety and efficacy with short- to mid-term follow-up results of UHP BA for PAS in children with congenital heart defects (CHD) in our center.MethodsThis is a retrospective cohort study in a single tertiary heart center. Children diagnosed with PAS associated with CHD were referred for UHP BA. All data with these children were collected for analysis with updated follow-up.ResultsA total of 37 UHP BAs were performed consecutively in 28 children. The success rate was 78.4%. A significantly (P = 0.005) larger ratio of the balloon to the minimal luminal diameter at the stenotic waist (balloon/waist ratio) was present in the success group (median 3.00, 1.64–8.33) compared to that in the failure group (median 1.94, 1.41 ± 4.00). Stepwise logistic regression analysis further identified that the balloon/waist ratio and the presence of therapeutic tears were two independent predictors of procedural success. The receiver operating characteristic curve revealed a cut-off value of 2.57 for the balloon/waist ratio to best differentiate success from failure cases. Signs of therapeutic tears were present in eight cases, all of whom were in the success group. Perioperative acute adverse events were recorded in 16 patients, including 11 pulmonary artery injuries, three pulmonary hemorrhages, and two pulmonary artery aneurysms. During a median follow-up period of 10.4 (0.1–21.0) months, nine cases experienced restenosis at a median time of 40 (4–325) days after angioplasty.ConclusionsThe UHP BA is safe and effective for the primary treatment of PAS in infants and children with CHD. The success rate is high with a low incidence of severe complications. The predictors of success are a larger balloon/waist ratio and the presence of therapeutic tears. The occurrence of restenosis during follow-up, however, remains a problem. A larger number of cases and longer periods of follow-up are needed for further study.

Keywords