Biosensors (May 2022)

Double Competitive Immunodetection of Small Analyte: Realization for Highly Sensitive Lateral Flow Immunoassay of Chloramphenicol

  • Dmitriy V. Sotnikov,
  • Lyubov V. Barshevskaya,
  • Anastasia V. Bartosh,
  • Anatoly V. Zherdev,
  • Boris B. Dzantiev

DOI
https://doi.org/10.3390/bios12050343
Journal volume & issue
Vol. 12, no. 5
p. 343

Abstract

Read online

A new scheme of reagents interaction for lateral flow immunoassay (LFIA) is proposed, which combines the features of competitive and sandwich assay and provides highly sensitive detection of low-molecular-weight analytes. Namely, the antigen in the sample interferes with the formation of the antibody (on the membrane)–hapten-protein–antibody (on the nanoparticle-marker) complex, competing with hapten-protein conjugate in both reactions. The proposed scheme was modelled using COPASI software, with a prediction of limit of detection (LOD) decrease by one order of magnitude compared to the standard competitive LFIA. This feature was experimentally confirmed for the detection of chloramphenicol (CAP) in honey. When tested in spiked honey, the visual LOD was 50 ng/mL for the common scheme and 5 ng/mL for the proposed scheme. Instrumental LOD was 300 pg/mL (1.2 µg/kg in conversion per sample weight of honey) in the standard scheme and 20 pg/mL (80 ng/kg in conversion per sample weight of honey) in the proposed scheme.

Keywords