Gongye shui chuli (Feb 2024)

Pesticide wastewater treatment by combination process of air flotation/iron-carbon /Fenton+ hydrolytic acidification+A/O+ contact oxidation

  • TIAN Qiping,
  • XU Meng,
  • LAI Liang,
  • XU Liya,
  • Zhang Feng,
  • YAO Huaqi

DOI
https://doi.org/10.19965/j.cnki.iwt.2023-0199
Journal volume & issue
Vol. 44, no. 2
pp. 190 – 193

Abstract

Read online

A combined process of air flotation/iron carbon microelectrolysis /Fenton+ hydrolytic acidification +A/O+ contact oxidation is used to treat pesticide wastewater . The results show that,when the influent COD,NH3-N and toluene concentrations are 7 866,56 and 53 mg/L,the treated effluent COD,NH3-N and toluene concentrations are 435,13 and 0.4 mg/L,respectively. The average removal rates of COD,NH3-N and toluene were 94.5%,81% and 99.2%,respectively. The drainage index reached the Class B standard of Quality Standard for Sewage Discharge into Urban Sewers (GB/T 31962—2015),and the process efficiency was reliable,which can provide reference for the design and construction of similar pesticide wastewater treatment.

Keywords