Effect of a 3D-printed reconstruction automated matching system for selecting the size of a left double-lumen tube: a study protocol for a prospective randomised controlled trial
Yi Xu,
Huaiming Wang,
Fei Wang,
Hongwei Zhang,
Hong Yu,
Lantao Li,
Yihao Zhu,
Feng Yin,
Fei Fei,
Wusong Liu,
Bowen Duan,
Ying Jia
Affiliations
Yi Xu
1 The Sixth Hospital of Wuhan, Affiliated Hospital of Jianghan University, Wuhan, Hubei, China
Huaiming Wang
1 Department of Anesthesiology, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, Sichuan, China
Fei Wang
School of Public Affairs, Xiamen University, Xiamen, China
Hongwei Zhang
1 Hospital and Institute of Obstetrics and Gynecology, Fudan University, Shanghai, China
Hong Yu
2 Department of Anesthesiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
Lantao Li
1 Department of Anesthesiology, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, Sichuan, China
Yihao Zhu
1 Department of Anesthesiology, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, Sichuan, China
Feng Yin
2 Department of Anesthesiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
Fei Fei
2 Department of Anesthesiology, West China Hospital of Sichuan University, Chengdu, Sichuan, China
Wusong Liu
3 Department of Endoscopy, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, Sichuan, China
Bowen Duan
3 Department of Endoscopy, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, Sichuan, China
Ying Jia
5 Department of Stomatology, Chengdu Medical College The First Affiliated Hospital, Chengdu, Sichuan, China
Introduction Lung isolation is primarily accomplished using a double-lumen tube (DLT) or bronchial blocker. A precise and accurate size of the DLT is a prerequisite for ensuring its accurate placement. Three-dimensional (3D) reconstruction technology can be used to accurately reproduce tracheobronchial structures to improve the accuracy of DLT size selection. Therefore, we have developed automatic comparison software for 3D reconstruction based on CT data (3DRACS). In this study, we aimed to evaluate the efficiency of using 3DRACS to select the DLT size for endobronchial intubation in comparison with using the ‘blind’ DLT intubation method to determine the DLT size, which is based on height and sex.Methods and analysis This is a prospective, single-centre, double-blind randomised controlled trial. In total, 200 patients scheduled for lung resection using a left DLT will be randomly allocated to the 3D group or the control group at a 1:1 ratio. A 3DRACS will be used for the 3D group to determine the size of the DLT, while in the case of the control group, the size of the DLT will be determined according to patient height and sex. The primary outcome is the success rate of placement of the left DLT without fibreoptic bronchoscopy (FOB). The secondary outcomes include the following: successful intubation time, degree of pulmonary atrophy, grade of airway injury, oxygenation during one-lung ventilation, postoperative sore throat and hoarseness, and number of times FOB is used.Ethics and dissemination Ethical approval has been obtained from our local ethics committee (approval number: SCCHEC-02-2022-155). Written informed consent will be obtained from all participants before randomisation, providing them with clear instructions about the purpose of the study. The results will be disseminated through peer-reviewed publications and conferences.Trial registration number NCT06258954.