Brain Stimulation (Mar 2024)

Systematic 1 Hz direct electrical stimulation for seizure induction: A reliable method for localizing seizure onset zone and predicting seizure freedom

  • Adithya Sivaraju,
  • Imran Quraishi,
  • Evan Collins,
  • Hari McGrath,
  • Alexander Ramos,
  • Nicholas B. Turk-Browne,
  • Hitten Zaveri,
  • Eyiyemisi Damisah,
  • Dennis D. Spencer,
  • Lawrence J. Hirsch

Journal volume & issue
Vol. 17, no. 2
pp. 339 – 345

Abstract

Read online

Objective: To prospectively investigate the utility of seizure induction using systematic 1 Hz stimulation by exploring its concordance with the spontaneous seizure onset zone (SOZ) and relation to surgical outcome; comparison with seizures induced by non-systematic 50 Hz stimulation was attempted as well. Methods: Prospective cohort study from 2018 to 2021 with ≥ 1 y post-surgery follow up at Yale New Haven Hospital. With 1 Hz, all or most of the gray matter contacts were stimulated at 1, 5, and 10 mA for 30–60s. With 50 Hz, selected gray matter contacts outside of the medial temporal regions were stimulated at 1–5 mA for 0.5–3s. Stimulation was bipolar, biphasic with 0.3 ms pulse width. The Yale Brain Atlas was used for data visualization. Variables were analyzed using Fisher's exact, χ2, or Mann–Whitney test. Results: Forty-one consecutive patients with refractory epilepsy undergoing intracranial EEG for localization of SOZ were included. Fifty-six percent (23/41) of patients undergoing 1 Hz stimulation had seizures induced, 83% (19/23) habitual (clinically and electrographically). Eighty two percent (23/28) of patients undergoing 50 Hz stimulation had seizures, 65% (15/23) habitual. Stimulation of medial temporal or insular regions with 1 Hz was more likely to induce seizures compared to other regions [15/32 (47%) vs. 2/41 (5%), p < 0.001]. Sixteen patients underwent resection; 11/16 were seizure free at one year and all 11 had habitual seizures induced by 1 Hz; 5/16 were not seizure free at one year and none of those 5 had seizures with 1 Hz (11/11 vs 0/5, p < 0.0001). No patients had convulsions with 1 Hz stimulation, but four did with 50 Hz (0/41 vs. 4/28, p = 0.02). Significance: Induction of habitual seizures with 1 Hz stimulation can reliably identify the SOZ, correlates with excellent surgical outcome if that area is resected, and may be superior (and safer) than 50 Hz for this purpose. However, seizure induction with 1 Hz was infrequent outside of the medial temporal and insular regions in this study.