Scientific Reports (Nov 2023)
Comparing corneal biomechanic changes among solo cataract surgery, microhook ab interno trabeculotomy and iStent implantation
Abstract
Abstract Minimally invasive glaucoma surgery has expanded the surgical treatment options in glaucoma, particularly when combined with cataract surgery. It is clinically relevant to understand the associated postoperative changes in biomechanical properties because they are influential on the measurement of intraocular pressure (IOP) and play an important role in the pathogenesis of open-angle glaucoma (OAG). This retrospective case–control study included OAG patients who underwent cataract surgery combined with microhook ab interno trabeculotomy (µLOT group: 53 eyes of 36 patients) or iStent implantation (iStent group: 59 eyes of 37 patients) and 62 eyes of 42 solo cataract patients without glaucoma as a control group. Changes in ten biomechanical parameters measured with the Ocular Response Analyzer and Corneal Visualization Scheimpflug Technology (Corvis ST) at 3 and 6 months postoperatively relative to baseline were compared among the 3 groups. In all the groups, IOP significantly decreased postoperatively. In the µLOT and control groups, significant changes in Corvis ST-related parameters, including stiffness parameter A1 and stress‒strain index, indicated that the cornea became softer postoperatively. In contrast, these parameters were unchanged in the iStent group. Apart from IOP reduction, the results show variations in corneal biomechanical changes from minimally invasive glaucoma surgery combined with cataract surgery.