E3S Web of Conferences (Jan 2018)

Numerical Simulations of SCR DeNOx System for a 660MW coal-fired power station

  • Yongqiang Deng,
  • Zhongming Mei,
  • Yijun Mao,
  • Nianping Liu,
  • Guoming Yin

DOI
https://doi.org/10.1051/e3sconf/20183804009
Journal volume & issue
Vol. 38
p. 04009

Abstract

Read online

Aimed at the selective catalytic reduction (SCR) DeNOx system of a 660 MW coal-fired power station, which is limited by low denitrification efficiency, large ammonia consumption and over-high ammonia escape rate, numerical simulations were conducted by employing STAR-CCM+ (CFD tool). The simulations results revealed the problems existed in the SCR DeNOx system. Aimed at limitations of the target SCR DeNOx system, factors affecting the denitrification performance of SCR, including the structural parameters and ammonia injected by the ammonia nozzles, were optimized. Under the optimized operational conditions, the denitrification efficiency of the SCR system was enhanced, while the ammonia escape rate was reduced below 3ppm. This study serves as references for optimization and modification of SCR systems.