Tehnika (Jan 2014)

Experimental determination of load bearing capacity of connections realized by punched metal plate fastener

  • Tekić Žikica M.,
  • Đorđević Saša M.

DOI
https://doi.org/10.5937/tehnika1405735T
Journal volume & issue
Vol. 69, no. 5
pp. 735 – 741

Abstract

Read online

This paper demonstrates the results of experimental determination of load bearing capacity of structural timber member connections realized by WOLF and LKVC metal connector plates. Considering the complexity of the connections realized by these modern mechanical fasteners, this paper deals only with plate anchorage capacity (stress in the metal-wood contact). The aim of the conducted experimental study was to determine the metal connector plate anchorage capacity in accordance with the provisions of Eurocode 5 and also to analyze the ratio of the load bearing capacities of these two types of connectors in terms of their geometry. Experimental testing was conducted by loading of multiple samples up to the limit plate anchorage capacity. Discussion of the test results included the analysis of the connection deformation for different levels of load, as well as the mode of reaching the limit plate anchorage capacity. Review of the determined limit plate anchorage capacities, for the determined displacements of connection, was given in the conclusion, together with the comment on test results.

Keywords