Brazilian Archives of Biology and Technology (Mar 2007)

A comparison between enzyme immunoassay and HPLC for ochratoxin A detection in green, roasted and instant coffee

  • Simone Fujii,
  • Elisabete Yurie Sataque Ono,
  • Ricardo Marcelo Reche Ribeiro,
  • Fernanda Garcia Algarte Assunção,
  • Cássia Reika Takabayashi,
  • Tereza Cristina Rocha Moreira de Oliveira,
  • Eiko Nakagawa Itano,
  • Yoshio Ueno,
  • Osamu Kawamura,
  • Elisa Yoko Hirooka

DOI
https://doi.org/10.1590/S1516-89132007000200020
Journal volume & issue
Vol. 50, no. 2
pp. 349 – 359

Abstract

Read online

An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) for ochratoxin A (OTA) detection in green, roasted and instant coffees was developed using anti-OTA monoclonal antibody. Immunological reagents prepared were OTA-BSA (4.76 mg/mL), anti-OTA.7 MAb (2x10³-fold dilution) and HRP-anti IgG (10³-fold dilution). The detection limit was 3.73 ng OTA/g and correlation coefficients (r) between this immunoassay and high performance liquid chromatography were 0.98 for green coffee, 0.98 for roasted and 0.86 for instant. OTA levels detected by ic-ELISA were higher than by HPLC, with ELISA/HPLC ratio of 0.66 - 1.46 (green coffee), 0.96 - 1.11 (roasted) and 0.93 - 1.82 (instant). ELISA recoveries for OTA added to coffee (5 - 70 ng/g) were 81.53 % for green coffee, 46.73 % for roasted and 64.35 % for instant, while recoveries by HPLC were 80.54 %, 45.91 % and 55.15 %, respectively. Matrices interferences were minimized by samples dilution before carrying out the ELISA assay. The results indicate that MAb-based ic-ELISA could be a simple, sensitive and specific screening tool for OTA detection, contributing to quality and safety of coffee products.ELISA competitivo indireto (ic-ELISA) baseado em anticorpos monoclonais foi desenvolvido para a detecção de ocratoxina A (OTA) em café verde, torrado e instantâneo. Os reagentes imunológicos necessários à reação consistiram de OTA-BSA (4,76 mg/mL), anti-OTA.7 MAb (diluído 2x10³) e anti IgG-HRP (diluído 10³), apresentando limite de detecção de 3,73 ng OTA/g. Os coeficientes de correlação (r) entre o imunoensaio e cromatografia líquida de alta eficiência (CLAE) foram de 0,98 (café verde), 0,98 (torrado) e 0,86 (instantâneo). Ic-ELISA detectou valores superestimados de OTA em relação a CLAE, com valor ELISA/CLAE variando de 0,66 - 1,46 (café verde), 0,96 - 1,11 (torrado) e 0,93 - 1,82 (instantâneo). As recuperações médias de OTA adicionada em café (5 - 70 ng/g) foram de 81,53 % (café verde), 46,73 % (torrado) e 64,35 % (instantâneo) por ELISA, em relação a 80,54 %, 45,91 % e 55,15 % por CLAE, respectivamente. A interferência de matriz no imunoensaio foi minimizada pela diluição das amostras previamente à análise por ELISA. O ic-ELISA desenvolvido pode ser considerado uma técnica alternativa simples, sensível e específica para análise de OTA, contribuindo para a qualidade e segurança de produtos de café.

Keywords