Arquivos Brasileiros de Cardiologia (May 2008)

Fatores biológicos e superestimação da fração de ejeção do ventrículo esquerdo no gated SPECT Biological factors and overestimation of left ventricular ejection fraction by gated SPECT

  • Marco Antônio Condé de Oliveira,
  • Paulo Schiavom Duarte,
  • Maria Margarita C. Gonzalez,
  • Valdir Ambrósio Moises,
  • Gilberto Alonso,
  • Eduardo Vilaça Lima,
  • Paola Emanuela Smanio,
  • Luiz Roberto Fernandes Martins,
  • Carlos A. R. Oliveira,
  • Luiz Eduardo Mastrocolla

DOI
https://doi.org/10.1590/S0066-782X2008000500005
Journal volume & issue
Vol. 90, no. 5
pp. 333 – 338

Abstract

Read online

FUNDAMENTO: Alguns pacientes apresentam fração de ejeção do ventrículo esquerdo (FEVE) superestimada na cintilografia miocárdica com sincronização eletrocardiográfica (gated SPECT). OBJETIVO: Estabelecer a relação entre fatores biológicos e FEVE superestimada. MÉTODOS: Selecionamos 3.838 pacientes que realizaram gated SPECT entre 20/5/2000 e 16/9/2005, com imagens normais de perfusão e FEVE >50%. Analisamos as variáveis: sexo (29,4% feminino e 70,6% masculino), idade (de 20 a 94 anos - média: 56 anos), peso (de 33,5 a 150 kg - média: 79,6 kg), altura (de 138 a 220 cm - média: 171 cm) e IMC (de 13,9 a 54 - média: 27,2). Em um subgrupo de 1.002 pacientes que realizaram ecocardiograma, incluímos as variáveis diâmetros diastólico (de 36 a 68 mm - média 47,5 mm) e sistólico (de 22 a 41 mm - média 29,8 mm). Dividimos os pacientes em dois grupos: FEVE normal (80%). A Razão de Chances (RC) para apresentar FEVE superestimada foi calculada para cada variável por regressão logística. RESULTADOS: Encontramos as seguintes Razões de Chances (p 0,2). No subgrupo de 1.002 pacientes, encontramos influência estatisticamente significativa na obtenção da FEVE superestimada para as variáveis diâmetro sistólico, sexo e altura. CONCLUSÃO: Apesar de o diâmetro sistólico influenciar na obtenção da FEVE superestimada, as variáveis sexo e altura apresentam influência independente na superestimação da FEVE pelo gated SPECT.BACKGROUND: Some patients present an overestimated left ventricular ejection fraction (LVEF) on electrocardiogram-gated myocardial scintigraphy (gated SPECT). OBJECTIVE: To establish the relationship between biological factors and overestimated LVEF. METHODS: We selected 3838 patients who underwent gated SPECT between May 20, 2000 and September 16, 2005 with normal perfusion images and LVEF >50%. The following variables were analyzed: gender (29.4% females and 70.6% males), age (from 20 to 94 years - mean: 56 years), weight (from 33.5 to 150 kg - mean: 79.6 kg), height (from 138 to 220 cm - mean: 171 cm) and BMI (from 13.9 to 54 - mean: 27.2). In a subgroup of 1002 patients who underwent echocardiogram, the diastolic diameter (from 36 to 68 mm - mean 47.5 mm) and systolic diameter (from 22 to 41 mm - mean 29.8 mm) variables were included. The patients were divided into two groups: normal LVEF (80%). The odds ratio (OR) for presenting an overestimated LVEF was calculated for each variable using logistic regression. RESULTS: The following odds ratios were found (p 0.2). In the subgroup of 1002 patients, a statistically significant influence was found in overestimated LVEF values for the systolic diameter, gender and height variables. CONCLUSION: Although systolic diameter influences the overestimation of LVEF, the gender and height variables have an independent influence on LVEF overestimation by gated SPECT.

Keywords