EPJ Web of Conferences (Jan 2017)

Design, Development & Functional Validation of Magnets system in support of 42 GHz Gyrotron in India

  • Pradhan S.,
  • Raj P.,
  • Prasad U.,
  • Ghate M.,
  • Khristi Y.,
  • Panchal A.,
  • Bhavsar D.,
  • Banudha M.,
  • Kedia S.,
  • Sharma A.N.,
  • Kanabar D.,
  • Parghi B.

DOI
https://doi.org/10.1051/epjconf/201714704005
Journal volume & issue
Vol. 147
p. 04005

Abstract

Read online

A multi institutional initiative is underway towards the development of 42 GHz, 200 kW gyrotron system in India under the frame work of Department of Science and Technology, Government of India. Indigenous realization comprising of design, fabrication, prototypes and functional validations of an appropriate Magnet System is one of the primary technological objective of these initiatives. The 42 GHz gyrotron magnet system comprises of a warm gun magnet, a NbTi/Cu based high homogenous superconducting cavity magnet and three warm collector magnets. The superconducting cavity magnet has been housed inside a low loss cryostat. The magnet system has been designed in accordance with gyrotron physics and engineering considerations respecting highly homogenous spatial field profile as well as maintaining steep gradient as per the compression and velocity ratios between the emission and resonator regions. The designed magnet system further ensures the co-linearity of the magnetic axis with that of the beam axis with custom winding techniques apart from a smooth collection of beam with the collector magnet profiles. The designed magnets have been wound after several R & D validations. The superconducting magnet has been housed inside a low loss designed cryostat with in-built radial and axial alignment flexibilities to certain extent. The cryostat further houses liquid helium port, liquid nitrogen ports, current communication ports, ports for monitoring helium level and other instrumentations apart from over-pressure safety intensive burst disks etc. The entire magnet system comprising of warm and superconducting magnets has been installed and integrated in the Gyrotron test set-up. The magnet system has been aligned in both warm and when the superconducting cavity magnet is cold. The integrated geometric axes have been experimentally ensured as well as the field profiles have been measured with the magnets being charged. Under experimental conditions, all magnets including the superconducting magnet have been charged to their nominal values with appropriate protection measures against the quench. This is the first time in India that a gyrotron specific magnet system with superconducting magnet has been realized.