Journal of Dentistry Indonesia (Oct 2015)

Pengaruh Minuman Kopi terhadap Perubahan Warna pada Resin Komposit

  • Aprilia Aprilia,
  • Linda Rochyani,
  • Erry Rahardianto

DOI
https://doi.org/10.14693/jdi.v14i3.838
Journal volume & issue
Vol. 14, no. 3
pp. 164 – 170

Abstract

Read online

Objective: The aim of this research was to investigate the influence of coffee beverage on hybrid composite resin discoloration. Material and method: This study used hybrid composite resin with A3 color, and was done by soaking composite resin plates in coffee solution for 1, 3, 5, and 7 days, corresponding to equivalent coffee usage for 6 months, 1, 1.5, and 2 years. The same measurements of reflectance were done before and after soaking into coffee solution. In the measurement, a beam from He-Ne laser is reflected by the sample to a photovoltaic cell type BOY-47, which provides a voltage signal accordig to the intensity of reflected light. Results: There was a significant difference between composite resin plates before and after soaking into coffee dilution for 1, 3, 5, and 7 days. Conclusion: Composite resin is discolored after soaking into a coffee solution, suggesting that coffee usage will have a discoloring effect on dental composite resin.

Keywords