Guoji Yanke Zazhi (Jan 2025)
Clinical diagnostic value of 18 MHz color Doppler ultrasonography in epiretinal membrane
Abstract
AIM: To explore the diagnostic value of 18 MHz color Doppler ultrasonography for epiretinal membrane.METHODS: A total of 44 cases(80 eyes)of patients with proposed diagnosis of cataract and vitreous opacity by fundus examination in our hospital between January 2020 and January 2022 were collected, and the affected eyes were examined by optical coherence tomography(OCT)and 18 MHz color Doppler ultrasonography, and the differences in the diagnostic sensitivity, specificity, and accuracy were compared between 18 MHz color Doppler ultrasonography and OCT for the diagnosis of epiretinal membrane.RESULTS: In the 80 eyes detected by 18 MHz color Doppler ultrasonography, 62 had epiretinal membrane and 18 had non epiretinal membrane. Totally 54 eyes were confirmed to have epiretinal membrane by OCT, 13 eyes were not diagnosed with epiretinal membrane, 5 eyes were missed diagnosis, and 8 eyes were misdiagnosed. The diagnostic consistency between 18 MHz color Doppler ultrasonography and OCT was high(Kappa=0.892, P0.05).CONCLUSION: 18 MHz color Doppler ultrasonography has some value in identifying epiretinal membrane lesions and is consistent with OCT testing.