Brain Sciences (Jul 2021)

Optimal Woven EndoBridge (WEB) Device Size Selection Using Automated Volumetric Software

  • Sameer Ansari,
  • Cynthia B. Zevallos,
  • Mudassir Farooqui,
  • Andres Dajles,
  • Sebastian Schafer,
  • Darko Quispe-Orozco,
  • Alan Mendez-Ruiz,
  • Samir Abdelkarim,
  • Sudeepta Dandapat,
  • Santiago Ortega-Gutierrez

DOI
https://doi.org/10.3390/brainsci11070901
Journal volume & issue
Vol. 11, no. 7
p. 901

Abstract

Read online

Introduction: Selecting the appropriate Woven EndoBridge (WEB) device sizing for the treatment of wide-neck bifurcation aneurysms (WNBAs) remains challenging. The aim of this study was to evaluate different volumetric-based imaging methodologies to predict an accurate WEB device size selection to result in a successful implantation. Methods: All consecutive patients treated with WEB devices for intracranial aneurysms from January 2019 to June 2020 were included. Aneurysm dimensions to calculate aneurysm volumes were measured using three different modalities: automated three-dimensional (3D) digital subtraction angiography (DSA), manual 3D DSA, and two-dimensional (2D) DSA. The device–aneurysm volume (DAV) ratio was defined as device volume divided by the aneurysm volume. WEB volumes and the DAV ratios were used for assessing the device implantation success and follow-up angiographic outcomes at six months. Pearson correlation, Wilcoxon Rank Sum test, and density approximations were used for estimating the WEB volumes and the imaging modality volumes for successful implantation. Results: A total of 41 patients with 43 aneurysms were included in the study. WEB device and aneurysm volume correlation coefficient was highest for 3D automatic (r = 0.943), followed by 3D manual (r = 0.919), and 2D DSA (r = 0.882) measurements. Measured median volumes were significantly different for 3D automatic and 2D DSA (p = 0.017). The highest rate of successful implantation (87.5%) was between 0.6 and 0.8 DAV ratio. Conclusion: Pre-procedural assessment of DAV ratios may increase WEB device implantation success. Our results suggest that volumetric measurements, especially using automated 3D volumes of the aneurysms, can assist in accurate WEB device size selection.

Keywords