IEEE Access (Jan 2018)

Achieving High Input PF for CRM Buck-Buck/Boost PFC Converter

  • Abdul Hakeem Memon,
  • Mazhar Hussain Baloach,
  • Anwar Ali Sahito,
  • Amir Mahmood Soomro,
  • Zubair Ahmed Memon

DOI
https://doi.org/10.1109/ACCESS.2018.2879804
Journal volume & issue
Vol. 6
pp. 79082 – 79093

Abstract

Read online

When the on-time is constant during a line cycle, the input power factor (PF) of critical conduction mode buck-buck/boost power factor correction converter is low. A variable on-time control (VOTC) scheme is put forward in this paper to realize high PF. By utilizing the input and output voltage to modulate the on-time of buck and buck/boost switch, we can realize high-input PF with low-total harmonic distortion within the universal input voltage range. The operating principles and the comparative analysis of the converter with conventional constant on-time control (COTC) and VOTC are analyzed. The proposed control scheme achieves high PF and efficiency as compared with the COTC. A 100-W prototype was built up to verify the effectiveness of the proposed control strategy.

Keywords