Scientific Reports (Apr 2023)
Optimal dose of normal saline for confirming correct peripheral venous access with precordial Doppler ultrasonography in children
Abstract
Abstract Precordial Doppler ultrasound technology can be utilized to confirm correct peripheral intravenous vascular (PIV) access in children during surgery. This study aimed to determine the minimally required dose of normal saline (NS) for confirming correct PIV access. Healthy children were randomly allocated to receive a 0.1 mL/kg, 0.3 mL/kg, or 0.5 mL/kg dose of NS injected via PIV access. Two independent raters judged the change in the recorded precordial Doppler sound test (S-test) before and after NS injection. Typically, rapid injection of NS increased the pitch of the heartbeat as the injection volume increased. Changes in blood flow velocity test (V-test) results were evaluated using a cut-off value of 1 cm/s. Both in the S- and V-tests, the detection rate of correct PIV access was lower with 0.1 mL/kg NS than with 0.3 mL/kg or 0.5 mL/kg. Logistic regression analysis showed that the positive results in both the S- and V-tests were significantly decreased with a 0.1 mL/kg NS; no significant difference was observed with a 0.3 mL/kg NS (reference dose: 0.5 mL/kg). These results suggest 0.3 mL/kg is the minimally required dose of NS for confirming correct PIV access. This study is registered with the University Hospital Medical Information Network (UMIN000041330).