Abstract

Read online

The ichroma™ IGRA-TB (Boditech Med Inc., Chuncheon, Republic of Korea) is an automated fluorescent immunoassay-based point-of-care interferon-gamma release assay for detecting latent tuberculosis infection. We evaluated this assay with 408 health care workers, and demonstrated its acceptable performances comparing to QuantiFERON-TB Gold-Plus (QFT-Plus; Qiagen, Germantown, MD).