BMC Ophthalmology (May 2023)
Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography
Abstract
Abstract Background To evaluate anterior segment structural alterations after implantable collamer lens (ICL) implantation in myopic patients using swept-source quantitative optical coherence tomography (SS-OCT). Methods This prospective study included 47 eyes in 24 patients with preoperative spherical equivalent ≥ -3.00 D. Patients underwent ICL implantation at Department of Ophthalmology, Peking University Third Hospital, from May 2021 to December 2022. SS-OCT was used to measure anterior chamber width (ACW), angle opening distance (AOD), angle recess area (ARA), trabecular-iris area (TISA), trabecular-iris angle (TIA), iridotrabecular contact (ITC) area, and ITC Index before ICL implantation surgery and at 1 month follow-up. The correlations among the ITC index, vault, and angle parameters were analysed. Receiver operating characteristic (ROC) analysis was used to explore the ability of the vault to identify eyes with suspected angle-closure. Results At one month following ICL implantation, the ITC area was 0.396 ± 0.37 mm2, and the ITC index is 8.143 ± 5.439%. All angle parameters, except ACW, showed a statistically significant reduction on SS-OCT (P 0.659 mm was found to be optimal for angle-closure suspect with a sensitivity of 85.2% and a specificity of 53.9%. Conclusions Anterior chamber angle parameters decreased one month after ICL implantation, and their percentage changes and ITC index correlated with the vault. When the vault is larger than 0.659 mm, it is necessary to be alert to possible closed angle suspicion.