Micromachines (Nov 2023)

A 40–50 GHz RF Front-End with Integrated Local Oscillator Leakage Calibration

  • Peigen Zhou,
  • Pinpin Yan,
  • Jixin Chen,
  • Zhe Chen,
  • Wei Hong

DOI
https://doi.org/10.3390/mi14112105
Journal volume & issue
Vol. 14, no. 11
p. 2105

Abstract

Read online

This article presents a transmitter (TX) front-end operating at frequencies covering 40–50 GHz, including a differential quadrature mixer with integrated amplitude and phase imbalance tuning, a power amplifier, and a detection mixer (DM) that supports local oscillator (LO) leakage signal or image signal calibration. Benefiting from the amplitude and phase imbalance tuning network of the in-phase quadrature (IQ) signal generator at the LO input, the TX exhibits more than 30 dBc image signal rejection over the full frequency band without any post-calibration. Based on the LO leakage signal fed back by the DM integrated at the RF output, the LO leakage of the TX has been improved by more than 10 dB through the LO leakage calibration module integrated in the quadrature mixer. When the intermediate frequency (IF) signal is fixed at 1 GHz, the TX’s 1 dB compressed output power (OP1 dB) is higher than 13.5 dBm over the operating band. Thanks to the LO leakage signal calibration unit and the IQ signal generator, the TX is compliant with the error vector magnitude (EVM) requirement of the IEEE 802.11aj standard up to the 64-quadrature amplitude modulation (QAM) operating mode.

Keywords