AIP Advances (Oct 2024)
Photoacoustic spectroscopy with a widely tunable narrowband fiber-feedback optical parametric oscillator
Abstract
Trace gas analysis is a key tool for the investigation of man-made environmental pollution as well as for early detection of respiratory diseases. To detect tiny concentrations, sensitive methods such as cavity ring down spectroscopy or plasmonic sensors have been used. Here, we demonstrate the combination of the photoacoustic effect in a classical cell with a novel, rapidly tunable, narrowband fiber-feedback optical parametric oscillator. The high sensitivity of photoacoustic cells and the extremely narrow linewidth as well as the wide and rapid tunability of the fiber-feedback optical parametric oscillator enable a high resolution of the rotational and vibrational bands of molecules in the near-infrared region. Photoacoustic spectra of methane, carbon dioxide, and water at ambient pressure are obtained in a broad spectral range and compared to high-resolution transmission molecular absorption database. In particular, scanning the entire carbon dioxide overtone around 4965 cm−1 at 2000 ppm takes 185 s with a signal-to-noise ratio of 31. This approach enables a wide tunability in the entire near- and mid-infrared spectral region suitable for many environmental and medical applications.