Engineering Applications of Computational Fluid Mechanics (Jan 2020)
Numerical investigation of the wet steam condensation flow characteristics in stator cascade with blade surface heating
Abstract
The scientific and effective control of steam wetness in steam turbines is of great significance for improving power generation efficiency. Based on the research status of wet steam, the influence of different surface heating intensity in a stator cascade was studied. The distribution of condensation flow parameters in White cascade under 0–700 kW/m2 surface heating intensity is calculated. On this basis, the positive heating intensity region was determined and refined to obtain the best heating condition with higher accuracy. The results show that the condensation is restrained and the outlet wetness is decreased as the blade surface heating intensity increases. The steam wetness and droplet diameter in the flow field can be controlled by adding heating intensity. Additionally, at the initial stage of applying heat to the blade, an increasing enthalpy drop occurs, and the entropy increase experiences a decline, while negative effects rapidly emerge if the heating intensity is too high. The optimum heating intensity is 120 kW/m2. Compared with the 0 kW/m2, the average outlet wetness, total pressure loss coefficient and entropy increase of 120 kW/m2 surface heating intensity can be reduced by 1.1266%, 15.5% and 1.7%, respectively, and the enthalpy drop can be increased by 1.7%.
Keywords